IPSCAPC Cable Assemblies Specification

IPSCAPC Cable Assemblies Specification

Short Description:

IPSCAPC Cable Assemblies Specification


  • Payment Terms: Paypal,western union,L/C,D/A,D/P,T/T
  • Description

    Specification

    Application

    Order information

    Questions&Comments

    Product Tags

    Features

    Cost effective solution for in house termination. 2.Low insertion loss and added loss.

    Height of attenuation.

    IP67 water, dust proof and corrosion resistant

    The material in the jumpel cable are all-weather and UV-resistant. 6.Mechanical performance: IEC 61754-4 standard.

    RoHS and REACH materials compliant. 8.Cable diameter Range: 5.0mm to 4.0* 7.0mm

     

     

    Item

    UPC (Ref: IEC 61755-3-1)

    APC (Ref: IEC 61755-3-2)

    Radius of curvature (mm)

    10 to 25

    5 to 12

    Fiber height (nm)

    -100 to 100

    -100 to 100

    Apex offset (μm)

    0 to 50

    0 to 50

    APC angle (°)

    /

    8° ±0.2°

    Key error (°)

    /

    0.2° max


     End-Face Qualty (SM)

     

    Zone Range (μm) Scratches Defects Reference
    A: Core 0 to 25 None None   

     

     

    IEC 61300-3-35:2015

    B: Cladding 25 to 115 None None
    C: Adhesive 115 to 135 None None
    D: Contact 135 to 250 None None
    E: Rest of ferrule None None

     

    End-Face Qualty (MM)

     

    Zone Range (μm) Scratches Defects Reference
    A: Core 0 to 65 None None   

     

     

     

    IEC 61300-3-35:2015

    B: Cladding 65 to 115 None None
    C: Adhesive 115 to 135 None None
    D: Contact 135 to 250 None None
    E: Rest of ferrule None None

     

    Mechanical Characteristics

     

    Test Conditions Reference
    Endurance 500 matings IEC 61300-2-2
    Vibration Frequency: 10 to 55Hz, Amplitude: 0.75mm IEC 61300-2-1
    Cable retention 100N (main cable); 50N (connector part) IEC 61300-2-4
    Strength of coupling mechanism 80N for 2 to 3mm cable IEC 61300-2-6
    Cable torsion 15N for 2 to 3mm cable IEC 61300-2-5
    Fall 10 drops, 1m drop height IEC 61300-2-12
    Static lateral load 1N for 1h (main cable); 0.2N for 5min (ranch part) IEC 61300-2-42
    Cold -25°C, 96h duration IEC 61300-2-17
    Dry heat +70°C, 96h duration IEC 61300-2-18
    Change of temperature -25°C to +70°C, 12 cycles IEC 61300-2-22
    Humidity +40°C at 93%, 96h duration IEC 61300-2-19

    Application

    Fiber optic communications in harsh outdoor environments Outdoor communication equipment connection

    waterproof fiber equipment SC port Remote wireless base station

    FTTx wiring project