Optical Return Loss Meter
Short Description:
Optical Return Loss Meter has multifunction testing mode, supports USB power supplying, and has simple interface, easy to operate, testing data can be stored and upload.Description
Specification
Application
Order information
Q&A
Product Tags
Reviews
Description
Overview
Optical Return Loss Meter has multifunction testing mode, supports USB power supplying, and has simple interface, easy to operate, testing data can be stored and upload. It is a significant performance parameter in system operation and fiber installation. There are frequently many insertion devices in an optical communication system. The energy emitted by each of these devices is partially or completely reflected back to the reflector. As a result, the reflector is harmed. This Optical Return Loss Meter is used to check the integrity of optical fiber connectors and measure refection attenuation in the optical link and various optical components. It can also be used as an optical RL measurement, optical power meter, optical source, or IL meter for on-site optimization. It has a data storage capability.
Features
1. Multifunction testing mode (RL、IL、OPM、OLS)
2. Testing data can be stored and upload
3. Supporting USB power supplying
4. Simple interface, easy to operate
Standard Configuration
1.unit……………………………………………………………………………….1 piece
2.operation instructions……………………………………………………..1 copy
3.Protective coat………………………………………………………………..1 piece
4.1.5V AA battery……………………………………………………………….3pieces
5.USB data wire…………………………………………………………………1piece
6.CD disc…………………………………………………………………………..1piece
7.FC/APC – FC/PC standard fiber……………………………………………1 cord
8.Cotton swabs…………………………………………………………………1 bag
9.Desiccant……………………………………………………………………..1 bag
10.5V USB adapter……………………………………………………………..1 piece
11.Certificate……………………………………………………………………..1 piece
12.Warranty card………………………………………………………………..1 piece
Operation Instructions
Specification
Optical RL Measurement |
|
Test wavelength(nm) |
1310/1550(±20) |
Spectral Width(nm) |
<5 |
Output Power(dBm) |
≥-5 |
Stability(dB/30min) |
±0.05 |
Test range(dB) |
0~70 |
Accuracy(dB) |
±0.5 |
Resolution (dB) |
0.01 |
Connection Type |
FC/APC |
Optical IL(meter) Mode |
|
Wavelength range(nm) |
800 ~ 1700 |
Calibration wavelength(nm) |
850、1300、1310、1490、 1550、 1625 |
Display unit |
dBm、dB、xW |
Test range(dBm) |
+6 ~-70 |
uncertainty(dB) |
±0.25 |
display |
LCD |
Communication interface |
USB |
Power(V) |
Three 1.5V AA batteries/USB powered |
Working temp(℃) |
-10~+60 |
Storage temp(℃) |
-25~+70 |
Relative humidity |
0~85%(non-condensing) |
dimensions(mm) |
180*90*36.5 |
weight(g ,excluding protective coat, battery) |
380 |
Notes:
1.the above Tech specifications are all tested in the T=23±2℃
2.requirement of 15mins warm up before testing
3.RL is tested in 0-60dB
4.tested when λ =1310nm,input power in the +6~-50dBm