DWDM SFP Optical Transceiver 2.67G for 80km
简短的介绍:
DWDM SFP Description The Baudcom DWDM SFP Transceiver is a high-performance optical module designed to meet the needs of DWDM SONET/SDH, Gigabit Ethernet, and Fiber-Channel applications. Featuring excellent wavelength stability and supporting operation at a 100 GHz channel, this cost-effective transceiver delivers reliable and efficient performance for long-…描述
规格
应用
命令
下载/常见问题
产品标签
评论
描述
DWDM SFP Description
The Baudcom DWDM SFP Transceiver is a high-performance optical module designed to meet the needs of DWDM SONET/SDH, Gigabit 以太网络, and Fiber-Channel applications. Featuring excellent wavelength stability and supporting operation at a 100 GHz channel, this cost-effective transceiver delivers reliable and efficient performance for long-range communication needs.
Equipped with a colded DFB laser in the transmitter section and an APD photodiode integrated with a TIA in the receiver section, this module ensures superior data transmission quality. It complies with Class I laser safety standards for secure operation. Additionally, the Baudcom 密集波分复用 SFP Transceiver offers advanced diagnostic monitoring capabilities, providing real-time insights into device parameters like transceiver temperature, laser bias current, optical power levels (transmitted and received), and supply voltage.
With wavelength selectability to the C-band ITU-T grid and compatibility with 100GHz channel spacing systems, this module ensures versatility and reliability in diverse network setups. Its extended link budget and low power dissipation make it an ideal solution for high-performance, long-range communications.
DWDM SFP 功能
Wavelength Selectable to C-band ITU-T grid wavelengths for flexible network integration
100GHz Channel Spacing compatibility, ideal for DWDM systems
DWDM SFP MSA Compliant, ensuring interoperability with standard systems
Up to 2.67Gb/s Data Rate for high-speed communication
OC48 Long Reach up to 80km, enabling extended distance transmission
Cold Start-up Wavelength Compliance for reliable operation even in cold environments
Low Power Dissipation of <1.3W maximum, reducing energy costs
Wide Operating Temperature Range of -5°C to 70°C, suitable for harsh environments
Advanced Diagnostic Monitoring for real-time tracking of temperature, voltage, laser bias current, transmit/receive optical power, and more
Extended Link Budget with APD receiver technology for improved sensitivity and signal integrity
RoHS Compliant and lead-free, ensuring environmental responsibility
绝对最大额定值
| 参数 | 符号 | 最小 | 马克斯 | 单元 |
| 电源电压1 | 电源电压3 | -0.5 | 4.0 | V |
| 电源电压2 | 电源电压5 | -0.5 | 6.0 | V |
| 储存温度 | TST | -40 | 85 | 摄氏度 |
| 光输入接收功率 | 销 | – | +4 | dBm的 |
运行条件
| 参数 | 符号 | 最小 | 典型 | 马克斯 | 单元 |
| 电源电压1 | 电源电压3 | 3.13 | 3.3 | 3.47 | V |
| 电源电流1 | ICC 3 | 750 | 嘛 | ||
| 电源电压2 | 电源电压5 | 4.75 | 5 | 5.25 | V |
| 电源电流2 | ICC5 | 500 | 嘛 | ||
| 工作外壳温度 | TCA | -5 | – | 70 | 摄氏度 |
| 模块功耗 | 下午 | – | 3.5 | w ^ |
发射器规格 - 光学
| 参数 | 符号 | 最小 | 典型 | 马克斯 | 单元 |
| 数据速率 多速率 | 姆拉 | 155 | 2667 | Mbps的 | |
| 中心波长(SOL)△ | LC | LC-25 | LC | LC+25 | 下午 |
| 中心波长(EOL)▲ | LC | 液晶-100 | LC | LC+100 | 下午 |
| 光发射功率 | 宝 | 0 | 2 | 4 | dBm的 |
| 光发射功率(禁用) | PTX_DISABLE | – | – | -40 | dBm的 |
| 消光比 | ER | 8.2 | – | 分贝 | |
| 通道间距 | 犳 | – | 100 | – | 千兆赫 |
| 抖动产生 | TJP-P | – | – | 70 | MUI |
| 频谱宽度(-20dB) | DL20 | – | 0.1 | 0.3 | 纳米 |
| 边模抑制比 | SMSR | 30 | – | – | 分贝 |
| 眼罩 | 符合 SONET/SDH 的贝尔核心 GR-253-CORE 和 ITU G.957 以及以太网和光纤通道的 IEEE 802.3ae | ||||
△激光-生命的开始
▲激光寿命终结
发射器规格 - 电气
| 参数 | 符号 | 最小 | 典型 | 马克斯 | 单元 |
| 电源电压 | VccTX | 3.13 | 3.3 | 3.47 | V |
| PECL/CML 输入 | VtxDIFF | 500 | – | 1600 | 毫伏 |
| 输入上升/下降 | TR / TF | – | – | 160 | PS |
| TX-故障 故障 | VF | 2 | – | VCC | V |
| TX-故障正常 | VN | V型 | – | V形+0.5 | V |
| TX_禁用
(断言) |
维生素D | 2 | – | VCC | V |
| TX_DISABLE(取反) | VDL | V型 | – | V型+0.8 | V |
APD 接收器规格 – 光学
| 参数 | 符号 | 最小 | 典型 | 马克斯 | 单元 |
| 接收器灵敏度
(OC48) |
– | -30 | -28 | dBm的 | |
| 最大输入功率 | RX 过载 | -9 | – | – | dBm的 |
| 输入工作波长 | λ | 1528 | – | 1564 | 纳米 |
| 反射率 | 器Rrx | – | – | -27 | 分贝 |
| 断言信号丢失 | -40 | – | – | dBm的 | |
| LOS 无效 | – | – | -32 | dBm的 | |
| LOS 迟滞 | 0.5 | – | – | 分贝 |
APD 接收器规格 - 电气
| 参数 | 符号 | 最小 | 典型 | 马克斯 | 单元 |
| 电源电压 | 接收端 | 3.13 | 3.3 | 3.47 | V |
| 差分输出摆幅 | VOUT PP | 370 | – | 2000 | 毫伏 |
| 上升/下降时间 | TR / TF | – | – | 175 | PS |
| 信号丢失——断言 | VOH | 2 | – | VCC | V |
| 信号丢失 – 无效 | VOL | V型 | – | V形+0.5 | V |
低速电信号时序
| 参数 | 符号 | 最小 | 典型 | 马克斯 | 单元 |
| TX 禁用负时间 | 吨 | – | – | 20 | 女士 |
| TX 禁用断言时间 | 关闭 | – | – | 20 | 女士 |
| 初始化时间,包括 TX_FAULT 的重置 | 初始化
|
– | – | 300 | 女士 |
| 启动时间 | t_启动 | – | – | 90 | 小号 |
| TX_FAULT/INT 断言时间 | t_故障 | – | – | 50 | 女士 |
| TX_DISABLE 复位 | t_重置 | 10 | – | – | 女士 |
| LOS 断言时间 | t_los_on | – | – | 100 | 我们 |
| LOS 负时间 | t_los_off | – | – | 100 | 我们 |
| 串行 ID 时钟速率 | f_串行_时钟 | – | – | 100 | 千赫 |
DWDM SFP C-band λc 波长指南
| 国际电联频道
产品代码 |
频率(太赫兹) | 波长 | 国际电联频道
产品代码 |
频率(太赫兹) | 波长 |
| 17 | 191.7 | 1563.86 | 40 | 194.0 | 1545.32 |
| 18 | 191.8 | 1563.05 | 41 | 194.1 | 1544.53 |
| 19 | 191.9 | 1562.23 | 42 | 194.2 | 1543.73 |
| 20 | 192.0 | 1561.42 | 43 | 194.3 | 1542.94 |
| 21 | 192.1 | 1560.61 | 44 | 194.4 | 1542.14 |
| 22 | 192.2 | 1559.79 | 45 | 194.5 | 1541.35 |
| 23 | 192.3 | 1558.98 | 46 | 194.6 | 1540.56 |
| 24 | 192.4 | 1558.17 | 47 | 194.7 | 1539.77 |
| 25 | 192.5 | 1557.36 | 48 | 194.8 | 1538.98 |
| 26 | 192.6 | 1556.55 | 49 | 194.9 | 1538.19 |
| 27 | 192.7 | 1555.75 | 50 | 195.0 | 1537.40 |
| 28 | 192.8 | 1554.94 | 51 | 195.1 | 1536.61 |
| 29 | 192.9 | 1554.13 | 52 | 195.2 | 1535.82 |
| 30 | 193.0 | 1553.33 | 53 | 195.3 | 1535.04 |
| 31 | 193.1 | 1552.52 | 54 | 195.4 | 1534.25 |
| 32 | 193.2 | 1551.72 | 55 | 195.5 | 1533.47 |
| 33 | 193.3 | 1550.92 | 56 | 195.6 | 1532.68 |
| 34 | 193.4 | 1550.12 | 57 | 195.7 | 1531.90 |
| 35 | 193.5 | 1549.32 | 58 | 195.8 | 1531.12 |
| 36 | 193.6 | 1548.51 | 59 | 195.9 | 1530.33 |
| 37 | 193.7 | 1547.72 | 60 | 196.0 | 1529.55 |
| 38 | 193.8 | 1546.92 | 61 | 196.1 | 1528.77 |
| 39 | 193.9 | 1546.12 |
EEPROM 串行 ID 存储器内容 (A0h):
| 数据地址 | 字段大小
(字节) |
值 | 的名字
领域 |
描述和内容 |
| 基本 ID 字段 | ||||
| 0 | 1 | 0BH | 识别码 | 串行收发器类型 |
| 1 | 1 | 24小时 | 分机。 标识符 | 串行收发器类型的扩展标识符 |
| 2 | 1 | 07H | 连接器 | 光连接器类型代号 |
| 3-10 | 8 | 00h,0Ch,44h,00h,80h,10h,01h,00h | 收发器 | 电子兼容性或光学兼容性代码 |
| 11 | 1 | 03H | 编码 | 串行编码算法代码 |
| 12 | 1 | 19H | BR,标称 | 标称波特率,单位100Mbps |
| 13-14 | 2 | 78小时(120公里) | 长度 (9μm) – 公里 | 9/125μm光纤支持的链路长度,单位为km |
| 15 | 1 | 46H | 最高温度 | 最高工作温度(°C) |
| 16 | 1 | FBh | 最低温度 | 最低工作外壳温度(°C) |
| 17 | 1 | 5FH | 最大电源电流 | 最大供电电流(以 4mA 为单位) |
| 18 | 1 | 00H | 保留的 | – |
| 19 | 1 | 41H | 通道间距及数量 | 信道间隔兼容性以及支持的 ITU 信道数量和调谐 |
| 20-35 | 16 | 模块相关 | 供应商名称 | SFP 供应商名称:“BAUDCOM”(ASCII) |
| 36 | 1 | 02H | 保留的 | 可选的 DWDM 功能 |
| 37-39 | 3 | – | 供应商OUI | SFP 收发器供应商 IEEE 公司 ID |
| 40-55 | 16 | GPD-XXXX-XX | 供应商PN | SFP 收发器提供的部件编号
供应商 (ASCII) |
| 56-59 | 4 | 模块相关 | 商Rev | 供应商提供的部件号的修订级别 (ASCII) |
| 60-61 | 2 | 模块相关 | 波长 | 激光波长(单位:nm) |
| 62 | 1 | 模块相关 | 波长 | 激光波长(以10pm为单位的小数部分) |
| 63 | 1 | 模块相关 | CC_BASE | 检查字节 0 – 62 的总和 |
扩展 ID 字段 |
||||
| 64-65 | 2 | 1AH | 选项 | 指示实施了哪些光 SFP 信号 |
| 66 | 1 | 00H | BR,最大 | 码率上限,单位为% |
| 67 | 1 | 00H | BR,分 | 较低码率余量,单位为% |
| 68-83 | 16 | 模块相关 | 供应商SN | 序列号 (ASCII) |
| 84-91 | 8 | 模块相关 | 日期代码 | 年(2 个字节)、月(2 个字节)、日(2 个字节) |
| 92 | 1 | 68H | 诊断型 | 指示收发器监控类型中实施的诊断类型 |
| 93 | 1 | F0H | 增强选项 | 指示实施了哪些可选增强功能选项 |
| 94 | 1 | 01H | SFF-8472 | “01”诊断(SFF-8472 修订版 9.3) |
| 95 | 1 | 模块相关 | CC_EX | 检查字节 64 – 94 的总和 |
| 供应商特定 ID 字段 | ||||
| 96-127 | 32 | – | 供应商特定 | 供应商特定 EEPROM(供应商特定数据;特定只读) |
| 128-255 | 128 | – | 保留的 | 保留供将来使用 |
序列 ID 内存内容:(A2H)
| 地址 | # 字节 | 名称 | 描述 |
| 00-55 | 56 | 警报和警告级别 | 温度/ Vcc/ 偏置电流/TX 功率/ RX 功率/ LD 温度/ TEC 电流、高/低警报和警告级别 |
| 56-94 | 39 | 不用于 DWDM 设备。 所有字节设置为 0。 | |
| 95 | 1 | 校验 | 字节0-94之和的低位8位 |
| 96-109 | 8 | A/D 值 | 以下增强诊断的 A/D 二进制值(实时):
模块温度、电源电压、激光器偏置电流、发射光功率、接收光功率、激光器温度和TEC电流。 这些值是内部校准的绝对测量值。 在这些地址位置中实现的所有诊断参数都有分配在地址位置 00-55 中的相应高低阈值、警报和警告阈值。 |
| 110 | 1 | 软控制信号 | 通过 2 线接入端口监控软控制信号。 可以更新以下控制信号的实时状态:TX_FAULT、TX_DISABLE、Rate Select 和 LOS。 |
| 111 | 1 | 保留的 | 保留的 |
| 112-117 | 5 | 警报/警告标志 | 可选警报和警告标志以及屏蔽位 对应于上面地址00-39中详述的级别。 |
| 118-119 | 2 | 警告面罩 | 分别对应字节116和117的警告位的屏蔽位 |
| 120-126 | 8 | 供应商特定 | 供应商特定数据 |
| 127 | 1 | 表选择 | 字节值定义后续读取的表位置
并写入字节位置 128-255 |
| 128-247 | 120 | 用户EEPROM | 用户可写EEPROM |
| 248-255 | 8 | 供应商特定 | 供应商特定的控制功能 |
数字诊断监控 A/D 精度
| 参数 | 范围 | 准确性 | 单元 |
| 温度 | -40~100 | ±3 | ℃ |
| 电压 | 0~Vcc | 0.1 | V |
| 偏置电流 | 0~120 | 5 | 嘛 |
| 发射功率 | 0~5 | ±2 | dBm的 |
| 接收功率 | -32~-8 | ±2 | dBm的 |
| TEC电流 | -1200~1200 | ±65 | 嘛 |
| 激光二极管温度 | 20~70 | ±0.25 | ℃ |
引脚定义
| 引脚数 | 名称 | 功能 | 参考。 |
| 1 | VEET | 发射机接地 | |
| 2 | TX_故障/中断 | 变送器故障 | 1 |
| 3 | TX_DISABLE | 发射器禁用 | 2 |
| 4 | MOD-DEF(2) | 模块定义2 | 3 |
| 5 | MOD-DEF(1) | 模块定义1 | 3 |
| 6 | MOD-DEF(0) | 模块定义 0 | 3 |
| 7 | 调入 | 费率选择 - 未实施 | |
| 8 | LOS | 信号丢失 | 4 |
| 9 | VEER | 接收器接地 | |
| 10 | VEER | 接收器接地 | |
| 11 | VEER | 接收器接地 | |
| 12 | RD- | 接收到的数据颠倒 | |
| 13 | RD + | 接收到的数据 | |
| 14 | VEER | 接收器接地 | |
| 15 | VCCR | 接收器功率 | |
| 16 | VCCT | 发射机功率 | |
| 17 | VEET | 发射机接地 | |
| 18 | TD + | 传输数据 | |
| 19 | TD- | 反向传输 | |
| 20 | VEET | 发射机接地 |
笔记:
- TX 故障是集电极开路/漏极输出,应使用 4.7K – 10K 上拉。 主板上的电阻。 上拉电压在 2.0V 和 VccT 之间,R+0.3V。 当高电平时,输出表明存在某种激光故障。 低表示正常运行。 在低电平状态下,输出将被拉至 < 0.8V。
- TX 禁用是用于关闭发射器光输出的输入。 它在模块内通过 4.7 – 10 K 电阻上拉。
- 这些是模块定义引脚。 应使用 4.7K – 10K 拉起它们。 主板上的电阻。 上拉电压应为 VccT 或 VccR(更多详细信息请参见第 IV 节)。
- LOS(信号丢失)是集电极开路/漏极输出,应使用 4.7K – 10K 上拉。 电阻器。 上拉电压在 2.0V 和 VccT 之间,R+0.3V。 当为高电平时,该输出表示接收到的光功率低于最坏情况下的接收器灵敏度(由所使用的标准定义)。 低表示正常运行。 在低电平状态下,输出将被拉至 < 0.8V。

图1。电气引脚详细信息

图2.DWDM SFP收发器上电初始化

图3. DWDM-SFP 框图

图4. 推荐的主板电源滤波网络

DWDM SFP Figure5. 机械尺寸
监管合规性
Baudcom SFP-DWDM 收发器设计符合 I 类激光安全标准,并通过以下标准认证:
| 激光安全 | FDA | CDRH 21 CFR 1040 和激光通知第 50 号 | 1120288-000 |
| 产品安全 | BST | EN 60825-1:2007
EN 60825-2:2004 EN 60950-1:2006 |
BST09082331721C-2 |
| 环境保护 | 中检集团 | RoHS 指令 2002/95/EC | RET090616001 |
| EMC | 华泰克 | EN 55022:2006+A1:2007
EN 55024:1998+A1+A2:2003 – |
WT10093768-DEE |
参考文献
- 小型可插拔模块 (SFP) 多源协议 (MSA),2000 年 9 月。
- IEEE802.3ae – 2002
- Telcordia GR-253-CORE
- “光收发器诊断监控接口”SFF-8472,修订版 9.3。
重要的提醒
本数据表中提供的性能数据、数据和任何说明性材料都是典型的,必须是
在适用于任何特定订单之前,由 BAUDCOM 以书面形式明确确认或
合同。 根据 BAUDCOM 的持续改进政策,规格可能会发生变化
不知不觉中。
本数据表中信息的发布并不意味着不受 BAUDCOM 或其他方的专利或其他保护权的约束。 更多详细信息可从任何 BAUDCOM 销售代表处获取。
规格
应用
用于 DWDM SONET/SDH 的 SFP 收发器
¡ 以太网 IEEE 802.3ae
¡ 光纤通道