DWDM SFP Optical Transceiver 2.67G for 80km

DWDM SFP Optical Transceiver 2.67G for 80km

简短的介绍:

DWDM SFP Description The Baudcom DWDM SFP Transceiver is a high-performance optical module designed to meet the needs of DWDM SONET/SDH, Gigabit Ethernet, and Fiber-Channel applications. Featuring excellent wavelength stability and supporting operation at a 100 GHz channel, this cost-effective transceiver delivers reliable and efficient performance for long-…
  • 付款条件:Paypal,西联汇款,L/C,D/A,D/P,T/T

  • 描述

    规格

    应用

    命令

    下载/常见问题

    产品标签

    评论

    描述

    DWDM SFP Description

    The Baudcom DWDM SFP Transceiver is a high-performance optical module designed to meet the needs of DWDM SONET/SDH, Gigabit 以太网络, and Fiber-Channel applications. Featuring excellent wavelength stability and supporting operation at a 100 GHz channel, this cost-effective transceiver delivers reliable and efficient performance for long-range communication needs.

    Equipped with a colded DFB laser in the transmitter section and an APD photodiode integrated with a TIA in the receiver section, this module ensures superior data transmission quality. It complies with Class I laser safety standards for secure operation. Additionally, the Baudcom 密集波分复用 SFP Transceiver offers advanced diagnostic monitoring capabilities, providing real-time insights into device parameters like transceiver temperature, laser bias current, optical power levels (transmitted and received), and supply voltage.

    With wavelength selectability to the C-band ITU-T grid and compatibility with 100GHz channel spacing systems, this module ensures versatility and reliability in diverse network setups. Its extended link budget and low power dissipation make it an ideal solution for high-performance, long-range communications.

    DWDM SFP 功能

    Wavelength Selectable to C-band ITU-T grid wavelengths for flexible network integration

    100GHz Channel Spacing compatibility, ideal for DWDM systems

    DWDM SFP MSA Compliant, ensuring interoperability with standard systems

    Up to 2.67Gb/s Data Rate for high-speed communication

    OC48 Long Reach up to 80km, enabling extended distance transmission

    Cold Start-up Wavelength Compliance for reliable operation even in cold environments

    Low Power Dissipation of <1.3W maximum, reducing energy costs

    Wide Operating Temperature Range of -5°C to 70°C, suitable for harsh environments

    Advanced Diagnostic Monitoring for real-time tracking of temperature, voltage, laser bias current, transmit/receive optical power, and more

    Extended Link Budget with APD receiver technology for improved sensitivity and signal integrity

    RoHS Compliant and lead-free, ensuring environmental responsibility

    绝对最大额定值

    参数 符号 最小 马克斯 单元
    电源电压1 电源电压3 -0.5 4.0 V
    电源电压2 电源电压5 -0.5 6.0 V
    储存温度 TST -40 85 摄氏度
    光输入接收功率 +4 dBm的

     

    运行条件

    参数 符号 最小 典型 马克斯 单元
    电源电压1 电源电压3 3.13 3.3 3.47 V
    电源电流1 ICC 3 750
    电源电压2 电源电压5 4.75 5 5.25 V
    电源电流2 ICC5 500
    工作外壳温度 TCA -5 70 摄氏度
    模块功耗 下午 3.5 w ^

     

    发射器规格 - 光学

    参数 符号 最小 典型 马克斯 单元
    数据速率 多速率 姆拉 155 2667 Mbps的
    中心波长(SOL)△ LC LC-25 LC LC+25 下午
    中心波长(EOL)▲ LC 液晶-100 LC LC+100 下午
    光发射功率 0 2 4 dBm的
    光发射功率(禁用) PTX_DISABLE -40 dBm的
    消光比 ER 8.2 分贝
    通道间距 100 千兆赫
    抖动产生 TJP-P 70 MUI
    频谱宽度(-20dB) DL20 0.1 0.3 纳米
    边模抑制比 SMSR 30 分贝
    眼罩 符合 SONET/SDH 的贝尔核心 GR-253-CORE 和 ITU G.957 以及以太网和光纤通道的 IEEE 802.3ae

    △激光-生命的开始

    ▲激光寿命终结

    发射器规格 - 电气

    参数 符号 最小 典型 马克斯 单元
    电源电压 VccTX 3.13 3.3 3.47 V
    PECL/CML 输入 VtxDIFF 500 1600 毫伏
    输入上升/下降 TR / TF 160 PS
    TX-故障 故障 VF 2 VCC V
    TX-故障正常 VN V型 V形+0.5 V
    TX_禁用

    (断言)

    维生素D 2 VCC V
    TX_DISABLE(取反) VDL V型 V型+0.8 V

    APD 接收器规格 – 光学

    参数 符号 最小 典型 马克斯 单元
    接收器灵敏度

    (OC48)

    -30 -28 dBm的
    最大输入功率 RX 过载 -9 dBm的
    输入工作波长 λ 1528 1564 纳米
    反射率 器Rrx -27 分贝
    断言信号丢失 -40 dBm的
    LOS 无效 -32 dBm的
    LOS 迟滞 0.5 分贝

     

    APD 接收器规格 - 电气

    参数 符号 最小 典型 马克斯 单元
    电源电压 接收端 3.13 3.3 3.47 V
    差分输出摆幅 VOUT PP 370 2000 毫伏
    上升/下降时间 TR / TF 175 PS
    信号丢失——断言 VOH 2 VCC V
    信号丢失 – 无效 VOL V型 V形+0.5 V

    低速电信号时序

    参数 符号 最小 典型 马克斯 单元
    TX 禁用负时间 20 女士
    TX 禁用断言时间 关闭 20 女士
    初始化时间,包括 TX_FAULT 的重置 初始化

     

    300 女士
    启动时间 t_启动 90 小号
    TX_FAULT/INT 断言时间 t_故障 50 女士
    TX_DISABLE 复位 t_重置 10 女士
    LOS 断言时间 t_los_on 100 我们
    LOS 负时间 t_los_off 100 我们
    串行 ID 时钟速率 f_串行_时钟 100 千赫

    DWDM SFP C-band λc 波长指南

    国际电联频道

    产品代码

    频率(太赫兹) 波长 国际电联频道

    产品代码

    频率(太赫兹) 波长
    17 191.7 1563.86 40 194.0 1545.32
    18 191.8 1563.05 41 194.1 1544.53
    19 191.9 1562.23 42 194.2 1543.73
    20 192.0 1561.42 43 194.3 1542.94
    21 192.1 1560.61 44 194.4 1542.14
    22 192.2 1559.79 45 194.5 1541.35
    23 192.3 1558.98 46 194.6 1540.56
    24 192.4 1558.17 47 194.7 1539.77
    25 192.5 1557.36 48 194.8 1538.98
    26 192.6 1556.55 49 194.9 1538.19
    27 192.7 1555.75 50 195.0 1537.40
    28 192.8 1554.94 51 195.1 1536.61
    29 192.9 1554.13 52 195.2 1535.82
    30 193.0 1553.33 53 195.3 1535.04
    31 193.1 1552.52 54 195.4 1534.25
    32 193.2 1551.72 55 195.5 1533.47
    33 193.3 1550.92 56 195.6 1532.68
    34 193.4 1550.12 57 195.7 1531.90
    35 193.5 1549.32 58 195.8 1531.12
    36 193.6 1548.51 59 195.9 1530.33
    37 193.7 1547.72 60 196.0 1529.55
    38 193.8 1546.92 61 196.1 1528.77
    39 193.9 1546.12

    EEPROM 串行 ID 存储器内容 (A0h):

    数据地址 字段大小

    (字节)

    的名字

    领域

    描述和内容
    基本 ID 字段
    0 1 0BH 识别码 串行收发器类型
    1 1 24小时 分机。 标识符 串行收发器类型的扩展标识符
    2 1 07H 连接器 光连接器类型代号
    3-10 8 00h,0Ch,44h,00h,80h,10h,01h,00h 收发器 电子兼容性或光学兼容性代码
    11 1 03H 编码 串行编码算法代码
    12 1 19H BR,标称 标称波特率,单位100Mbps
    13-14 2 78小时(120公里) 长度 (9μm) – 公里 9/125μm光纤支持的链路长度,单位为km
    15 1 46H 最高温度 最高工作温度(°C)
    16 1 FBh 最低温度 最低工作外壳温度(°C)
    17 1 5FH 最大电源电流 最大供电电流(以 4mA 为单位)
    18 1 00H 保留的
    19 1 41H 通道间距及数量 信道间隔兼容性以及支持的 ITU 信道数量和调谐
    20-35 16 模块相关 供应商名称 SFP 供应商名称:“BAUDCOM”(ASCII)
    36 1 02H 保留的 可选的 DWDM 功能
    37-39 3 供应商OUI SFP 收发器供应商 IEEE 公司 ID
    40-55 16 GPD-XXXX-XX 供应商PN SFP 收发器提供的部件编号

    供应商 (ASCII)

    56-59 4 模块相关 商Rev 供应商提供的部件号的修订级别 (ASCII)
    60-61 2 模块相关 波长 激光波长(单位:nm)
    62 1 模块相关 波长 激光波长(以10pm为单位的小数部分)
    63 1 模块相关 CC_BASE 检查字节 0 – 62 的总和

    扩展 ID 字段

    64-65 2 1AH 选项 指示实施了哪些光 SFP 信号
    66 1 00H BR,最大 码率上限,单位为%
    67 1 00H BR,分 较低码率余量,单位为%
    68-83 16 模块相关 供应商SN 序列号 (ASCII)
    84-91 8 模块相关 日期代码 年(2 个字节)、月(2 个字节)、日(2 个字节)
    92 1 68H 诊断型 指示收发器监控类型中实施的诊断类型
    93 1 F0H 增强选项 指示实施了哪些可选增强功能选项
    94 1 01H SFF-8472 “01”诊断(SFF-8472 修订版 9.3)
    95 1 模块相关 CC_EX 检查字节 64 – 94 的总和
    供应商特定 ID 字段
    96-127 32 供应商特定 供应商特定 EEPROM(供应商特定数据;特定只读)
    128-255 128 保留的 保留供将来使用

     

     序列 ID 内存内容:(A2H)

    地址 # 字节 名称 描述
    00-55 56 警报和警告级别 温度/ Vcc/ 偏置电流/TX 功率/ RX 功率/ LD 温度/ TEC 电流、高/低警报和警告级别
    56-94 39 不用于 DWDM 设备。 所有字节设置为 0。
    95 1 校验 字节0-94之和的低位8位
    96-109 8 A/D 值 以下增强诊断的 A/D 二进制值(实时):

    模块温度、电源电压、激光器偏置电流、发射光功率、接收光功率、激光器温度和TEC电流。 这些值是内部校准的绝对测量值。 在这些地址位置中实现的所有诊断参数都有分配在地址位置 00-55 中的相应高低阈值、警报和警告阈值。

    110 1 软控制信号 通过 2 线接入端口监控软控制信号。 可以更新以下控制信号的实时状态:TX_FAULT、TX_DISABLE、Rate Select 和 LOS。
    111 1 保留的 保留的
    112-117 5 警报/警告标志 可选警报和警告标志以及屏蔽位 对应于上面地址00-39中详述的级别。
    118-119 2 警告面罩 分别对应字节116和117的警告位的屏蔽位
    120-126 8 供应商特定 供应商特定数据
    127 1 表选择 字节值定义后续读取的表位置

    并写入字节位置 128-255

    128-247 120 用户EEPROM 用户可写EEPROM
    248-255 8 供应商特定 供应商特定的控制功能

    数字诊断监控 A/D 精度

    参数 范围 准确性 单元
    温度 -40~100 ±3
    电压 0~Vcc 0.1 V
    偏置电流 0~120 5
    发射功率 0~5 ±2 dBm的
    接收功率 -32~-8 ±2 dBm的
    TEC电流 -1200~1200 ±65
    激光二极管温度 20~70 ±0.25

     

    引脚定义

    引脚数 名称 功能 参考。
    1 VEET 发射机接地
    2 TX_故障/中断 变送器故障 1
    3 TX_DISABLE 发射器禁用 2
    4 MOD-DEF(2) 模块定义2 3
    5 MOD-DEF(1) 模块定义1 3
    6 MOD-DEF(0) 模块定义 0 3
    7 调入 费率选择 - 未实施
    8 LOS 信号丢失 4
    9 VEER 接收器接地
    10 VEER 接收器接地
    11 VEER 接收器接地
    12 RD- 接收到的数据颠倒
    13 RD + 接收到的数据
    14 VEER 接收器接地
    15 VCCR 接收器功率
    16 VCCT 发射机功率
    17 VEET 发射机接地
    18 TD + 传输数据
    19 TD- 反向传输
    20 VEET 发射机接地

    笔记:

    1. TX 故障是集电极开路/漏极输出,应使用 4.7K – 10K 上拉。 主板上的电阻。 上拉电压在 2.0V 和 VccT 之间,R+0.3V。 当高电平时,输出表明存在某种激光故障。 低表示正常运行。 在低电平状态下,输出将被拉至 < 0.8V。
    2. TX 禁用是用于关闭发射器光输出的输入。 它在模块内通过 4.7 – 10 K 电阻上拉。
    3. 这些是模块定义引脚。 应使用 4.7K – 10K 拉起它们。 主板上的电阻。 上拉电压应为 VccT 或 VccR(更多详细信息请参见第 IV 节)。
    4. LOS(信号丢失)是集电极开路/漏极输出,应使用 4.7K – 10K 上拉。 电阻器。 上拉电压在 2.0V 和 VccT 之间,R+0.3V。 当为高电平时,该输出表示接收到的光功率低于最坏情况下的接收器灵敏度(由所使用的标准定义)。 低表示正常运行。 在低电平状态下,输出将被拉至 < 0.8V。

    dwdm sfp

      图1。电气引脚详细信息

    图2.DWDM SFP收发器上电初始化

    图3. DWDM-SFP 框图

    图4. 推荐的主板电源滤波网络

    dwdm sfp

    DWDM SFP Figure5. 机械尺寸

    监管合规性

    Baudcom SFP-DWDM 收发器设计符合 I 类激光安全标准,并通过以下标准认证:

    激光安全 FDA CDRH 21 CFR 1040 和激光通知第 50 号 1120288-000
    产品安全 BST EN 60825-1:2007

    EN 60825-2:2004

    EN 60950-1:2006

    BST09082331721C-2
    环境保护 中检集团 RoHS 指令 2002/95/EC RET090616001
    EMC 华泰克 EN 55022:2006+A1:2007

    EN 55024:1998+A1+A2:2003 –

    WT10093768-DEE

    参考文献

    1. 小型可插拔模块 (SFP) 多源协议 (MSA),2000 年 9 月。
    2. IEEE802.3ae – 2002
    3. Telcordia GR-253-CORE
    4. “光收发器诊断监控接口”SFF-8472,修订版 9.3。

    重要的提醒

    本数据表中提供的性能数据、数据和任何说明性材料都是典型的,必须是

    在适用于任何特定订单之前,由 BAUDCOM 以书面形式明确确认或

    合同。 根据 BAUDCOM 的持续改进政策,规格可能会发生变化

    不知不觉中。

    本数据表中信息的发布并不意味着不受 BAUDCOM 或其他方的专利或其他保护权的约束。 更多详细信息可从任何 BAUDCOM 销售代表处获取。

    规格
    应用

    用于 DWDM SONET/SDH 的 SFP 收发器

    ¡ 以太网 IEEE 802.3ae

    ¡ 光纤通道

    命令
    产品型号 描述 查询
    BXD-XX48-04C DWDM SFP,XX=17~61(ITU 通道 C 频段),2.67Gbps,40km,-5oC ~ +70oC, 询价
    XD-XX48-04D DWDM SFP, XX=17~61 (ITU Channel C-band), 2.67Gbps, 40km, -5oC ~ +70oC, 数字诊断监控 询价
    下载/常见问题
    产品标签
    评论

    0条评论

    5

    5 开始 5 0
    4 开始 4 0
    3 开始 3 0
    2 开始 2 0
    1 开始 1 0

    Captcha