CWDM transceiver SFP 2.67Gbps 120km Reach
Short Description:
Maximize your network’s performance and reach with our industrial-grade CWDM transceiver SFP, engineered to deliver reliable 120km transmission at 2.67Gbps data rates.Its robust construction featuring 8 CWDM DFB wavelengths laser and an APD photodetector for superior sensitivity and long-distance performance. Fully compliant with SFP MSA and SFF-8472 s…Description
Specification
Application
Order
Downloads/FAQ
Product Tags
Reviews
Description
Maximize your network’s performance and reach with our industrial-grade CWDM transceiver SFP, engineered to deliver reliable 120km transmission at 2.67Gbps data rates.Its robust construction featuring 8 CWDM DFB wavelengths laser and an APD photodetector for superior sensitivity and long-distance performance. Fully compliant with SFP MSA and SFF-8472 standards, it offers seamless compatibility with a wide range of networking equipment. The integrated Digital Diagnostic Monitoring (DDM) function provides real-time oversight of temperature, voltage, and optical power through an I2C interface, enabling predictive maintenance and network optimization. Designed with a +3.3V single power supply and RoHS compliance, this CWDM transceiver supports critical applications including SDH STM-16, SONET OC-48 systems, 2X Fibre Channel, and core switch-to-switch interfaces.
CWDM transceiver SFP Features
Long-Distance Optical Performance
Supports transmission distances up to 120 kilometers over single-mode fiber (SMF), making it perfect for metropolitan area network (MAN) applications and connecting dispersed data centers.
Utilizes a high-quality, uncooled CWDM DFB laser transmitter and an Avalanche Photodiode (APD) receiver to ensure excellent signal clarity and reception sensitivity over the entire link.
Advanced Digital Diagnostics & Monitoring
Implements full SFF-8472 compliant Digital Diagnostic Monitoring (DDM) with internal calibration.
Provides real-time, accessible monitoring of key parameters: Transmitted Optical Power, Received Optical Power, Laser Bias Current, Supply Voltage, and Module Temperature.
This feature enables proactive network management, helps in troubleshooting, and prevents unexpected downtime.
Broad Compatibility & Standards Compliance
Hot-pluggable SFP form factor with a duplex LC receptacle for easy installation and upgrades.
Fully compliant with SFP Multi-Source Agreement (MSA) standards, ensuring interoperability with a vast array of switches, routers, and media converters from major vendors.
Designed to meet Class I laser safety requirements and is RoHS compliant, adhering to international safety and environmental regulations.
Reliable Operation & Design
Operates on a single +3.3V power supply, simplifying host board design.
Features a standard industrial operating case temperature range of 0°C to +70°C, ensuring stable performance in typical equipment environments.
Includes essential host interfaces such as TX Disable, TX Fault, and Loss of Signal (LOS) indicators for comprehensive link management.
CWDM transceiver
Module Block Diagram
Absolute Maximum Ratings
Table 1 – Absolute Maximum Ratings
|
Parameter |
Symbol |
Min |
Max |
Unit |
|
Supply Voltage |
Vcc |
-0.5 |
4.5 |
V |
|
Storage Temperature |
Ts |
-40 |
+85 |
°C |
|
Operating Humidity |
– |
5 |
85 |
% |
Recommended Operating Conditions
Table 2 – Recommended Operating Conditions
|
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
|
|
Operating Case Temperature |
Standard |
Tc |
0 |
|
+70 |
°C |
|
Power Supply Voltage |
Vcc |
3.13 |
3.3 |
3.47 |
V |
|
|
Power Supply Current |
Icc |
|
|
300 |
mA |
|
|
Data Rate |
|
|
2.67 |
|
Gbps |
|
BD-XX48-08CD
See table3 below for “xx” values
Table3 -λC Wavelength Guide
|
λC Wavelength Guide |
|||||
|
Code |
λC |
Unit |
Code |
λC |
Unit |
|
47 |
1470 |
nm |
57 |
1570 |
nm |
|
49 |
1490 |
nm |
59 |
1590 |
nm |
|
51 |
1510 |
nm |
61 |
1610 |
nm |
|
53 |
1530 |
nm |
|
|
|
|
55 |
1550 |
nm |
|
|
|
Optical and Electrical Characteristics
BD-XX48-08CD: (CWDM and APD, 120km Reach)
Table 4 – Optical and Electrical Characteristics
|
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Notes |
||
|
Transmitter |
||||||||
|
Centre Wavelength |
λc |
λc-6.5 |
λc |
λc+6.5 |
nm |
|
||
|
Spectral Width (-20dB) |
∆λ |
|
|
1 |
nm |
|
||
|
Side Mode Suppression Ratio |
SMSR |
30 |
|
|
dB |
|
||
|
Average Output Power |
Pout |
0 |
|
5 |
dBm |
1 |
||
|
Extinction Ratio |
ER |
9 |
|
|
dB |
|
||
|
Optical Rise/Fall Time (20%~80%) |
tr/tf |
|
|
150 |
ps |
|
||
|
Data Input Swing Differential |
VIN |
400 |
|
1800 |
mV |
2 |
||
|
Input Differential Impedance |
ZIN |
90 |
100 |
110 |
Ω |
|
||
|
TX Disable |
Disable |
|
2.0 |
|
Vcc |
V |
|
|
|
Enable |
|
0 |
|
0.8 |
V |
|
||
|
TX Fault |
Fault |
|
2.0 |
|
Vcc |
V |
|
|
|
Normal |
|
0 |
|
0.8 |
V |
|
||
|
Receiver |
||||||||
|
Receiver Sensitivity |
|
|
|
-28 |
dBm |
3 |
||
|
Receiver Overload |
|
-9 |
|
|
dBm |
3 |
||
|
LOS De-Assert |
LOSD |
|
|
-30 |
dBm |
|
||
|
LOS Assert |
LOSA |
-40 |
|
|
dBm |
|
||
|
LOS Hysteresis |
|
1 |
|
4 |
dB |
|
||
|
Data Output Swing Differential |
Vout |
370 |
|
1800 |
mV |
4 |
||
|
LOS |
High |
2.0 |
|
Vcc |
V |
|
||
|
Low |
|
|
0.8 |
V |
|
|||
Notes:
1. The optical power is launched into SMF.
2. PECL input, internally AC-coupled and terminated.
3. Measured with a PRBS 223-1 test pattern @2488Mbps, BER ≤1×10-12.
4. Internally AC-coupled.
Timing and Electrical
Table 5 – Timing and Electrical
|
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
|
Tx Disable Negate Time |
t_on |
|
|
1 |
ms |
|
Tx Disable Assert Time |
t_off |
|
|
10 |
μs |
|
Time To Initialize, including Reset of Tx Fault |
t_init |
|
|
300 |
ms |
|
Tx Fault Assert Time |
t_fault |
|
|
100 |
μs |
|
Tx Disable To Reset |
t_reset |
10 |
|
|
μs |
|
LOS Assert Time |
t_loss_on |
|
|
100 |
μs |
|
LOS De-assert Time |
t_loss_off |
|
|
100 |
μs |
|
Serial ID Clock Rate |
f_serial_clock |
|
|
400 |
KHz |
|
MOD_DEF (0:2)-High |
VH |
2 |
|
Vcc |
V |
|
MOD_DEF (0:2)-Low |
VL |
|
|
0.8 |
V |
CWDM transceiver SFP Diagnostics
Table 5 – Diagnostics Specification
|
Parameter |
Range |
Unit |
Accuracy |
Calibration |
|
Temperature |
0 to +70 |
°C |
±3°C |
Internal / External |
|
Voltage |
3.0 to 3.6 |
V |
±3% |
Internal / External |
|
Bias Current |
0 to 100 |
mA |
±10% |
Internal / External |
|
TX Power |
0 to +5 |
dBm |
±3dB |
Internal / External |
|
RX Power |
-30 to -9 |
dBm |
±3dB |
Internal / External |
Digital Diagnostic Memory Map
The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA).
The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring.
The digital diagnostic memory map specific data field defines as following.
Pin Definitions
Pin Diagram
Pin Descriptions
|
Pin |
Signal Name |
Description |
Plug Seq. |
Notes |
|
1 |
VEET |
Transmitter Ground |
1 |
|
|
2 |
TX FAULT |
Transmitter Fault Indication |
3 |
Note 1 |
|
3 |
TX DISABLE |
Transmitter Disable |
3 |
Note 2 |
|
4 |
MOD_DEF(2) |
SDA Serial Data Signal |
3 |
Note 3 |
|
5 |
MOD_DEF(1) |
SCL Serial Clock Signal |
3 |
Note 3 |
|
6 |
MOD_DEF(0) |
TTL Low |
3 |
Note 3 |
|
7 |
Rate Select |
Not Connected |
3 |
|
|
8 |
LOS |
Loss of Signal |
3 |
Note 4 |
|
9 |
VEER |
Receiver ground |
1 |
|
|
10 |
VEER |
Receiver ground |
1 |
|
|
11 |
VEER |
Receiver ground |
1 |
|
|
12 |
RD- |
Inv. Received Data Out |
3 |
Note 5 |
|
13 |
RD+ |
Received Data Out |
3 |
Note 5 |
|
14 |
VEER |
Receiver ground |
1 |
|
|
15 |
VCCR |
Receiver Power Supply |
2 |
|
|
16 |
VCCT |
Transmitter Power Supply |
2 |
|
|
17 |
VEET |
Transmitter Ground |
1 |
|
|
18 |
TD+ |
Transmit Data In |
3 |
Note 6 |
|
19 |
TD- |
Inv. Transmit Data In |
3 |
Note 6 |
|
20 |
VEET |
Transmitter Ground |
1 |
|
CWDM transceiver Notes:
Plug Seq.: Pin engagement sequence during hot plugging.
1) TX Fault is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor on the host board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8V.
2) TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7k~10kΩ resistor. Its states are:
Low (0 to 0.8V): Transmitter on
(>0.8V, < 2.0V): Undefined
High (2.0 to 3.465V): Transmitter Disabled
Open: Transmitter Disabled
3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on the host board. The pull-up voltage shall be VccT or VccR.
Mod-Def 0 is grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4) LOS is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor. Pull up voltage between 2.0V and Vcc+0.3V. Logic 1 indicates loss of signal; Logic 0 indicates normal operation. In the low state, the output will be pulled to less than 0.8V.
5) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES.
6) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the mod
Recommended Interface Circuit
Mechanical Dimensions
Regulatory Compliance
BAUDCOM SFP transceiver is designed to be Class I Laser safety compliant and is certified per the following standards
|
Feature |
Agency |
Standard |
Certificate / Comments |
| Laser Safety |
FDA |
CDRH 21 CFR 1040 annd Laser Notice No. 50 | 1120294-000 |
| Product Safety |
BST |
EN 60825-1:2007
EN 60825-2:2004 EN 60950-1:2006 |
BT0905142002 |
| Environmental protection |
SGS |
RoHS Directive 2002/95/EC | GZ0902008346/CHEM |
| EMC |
CCIC |
EN 55022:2006+A1:2007
EN 55024:1998+A1:2001+A2:2003 |
CTE09050018 |
Specification
Application
Applications
¨ SDH STM-16 and SONET OC-48 system
¨ 2X Fiber Channel
¨ Switch to Switch interface
¨ Switched backplane applications
¨ Router/Server interface
¨ Other optical transmission systems