Rack Mount PLC Splitter 1U 19 inch for FTTX network - Baudcom

Rack Mount PLC Splitter 1U 19 inch for FTTX network

Rack Mount PLC Splitter 1U 19 inch for FTTX network

Short Description:

Rack Mount PLC Splitter 1U 19 inch for FTTX network Rack Mount PLC Splitter Features: ◆    Uniform power splitting ◆    Compact package dimension ◆    Low polarization dependent loss ◆    Good channel-to-channel uniformity ◆    Environmentally and mechanically stable ◆    Low Insertion Loss and high Return Loss ◆    Wide operating wavelength range from1260nm…
  • Payment Terms: Paypal,western union,L/C,D/A,D/P,T/T

  • Description

    Order information

    Q&A

    Product Tags

    Reviews

    Description

    Rack Mount PLC Splitter 1U 19 inch for FTTX network

    Rack Mount PLC Splitter Features:

    ◆    Uniform power splitting

    ◆    Compact package dimension

    ◆    Low polarization dependent loss

    ◆    Good channel-to-channel uniformity

    ◆    Environmentally and mechanically stable

    ◆    Low Insertion Loss and high Return Loss

    ◆    Wide operating wavelength range from1260nm to 1650nm

    Standard:

    ◆     Telcordia GR-1209 and GR-1221

     Application:

    ◆     Telecommunication networks

    ◆     FTTX, FTTH (Fiber to the Home)

    ◆     PON (Passive Optical Network)

    ◆     LAN & WAN

    ◆     CATV

    Specifications:

    Table 1: Performance for 1×N PLC Splitter

    Note: All measurements are done at room temperature without connectors.

    Port Configuration 1×2 1×4 1×8 1×16 1×32 1×64
    Operating Wavelength (nm) 1260~1650
    Insertion Loss (dB) Typ. 3.6 6.8 10.0 13.0 16.0 19.5
    Max. 4.0 7.3 10.5 13.7 16.9 21.0
    Loss Uniformity (dB) Typ. 0.4 0.5 0.5 1.0 1.0 1.5
    Max. 0.6 0.6 0.8 1.2 1.5 2.5
    Return Loss (dB) 55 55 55 55 55 55
    PDL (dB) Typ. 0.1 0.1 0.1 0.1 0.2 0.2
    Max. 0.2 0.2 0.3 0.3 0.3 0.4
    Directivity (dB) 55 55 55 55 55 55
    Fiber Length (m) 1.0 or customized
    Fiber Type Corning SMF-28e or customized
    Wavelength Dependent Loss (dB) Typ. 0.2 0.2 0.2 0.3 0.3 0.3
    Max. 0.3 0.3 0.3 0.5 0.5 0.5
    Temperature Stability (-40~+85°C) (dB) Typ. 0.3 0.3 0.3 0.4 0.4 0.4
    Max. 0.5 0.5 0.5 0.5 0.5 0.5
    Operating Temperature (°C) -40~+85°C
    Storage Temperature (°C) -40~+85°C

     

    Table 2: Performance for 1×N 1U Rack mount Fiber PLC Splitter

    Note: All measurements are done at room temperature with connectors.

    Port Configuration 1×2 1×4 1×8 1×16 1×32 1×64
    Operating Wavelength (nm) 1260~1650
    Insertion Loss (dB) Typ. 4.0 7.0 10.3 13.5 16.5 20.0
    Max. 4.5 7.7 11.0 14.2 17.5 21.5
    Loss Uniformity (dB) Typ. 0.4 0.5 0.5 1.0 1.0 1.5
    Max. 0.6 0.6 0.8 1.2 1.5 2.5
    Return Loss (dB) 55 55 55 55 55 55
    PDL (dB) Typ. 0.1 0.1 0.1 0.1 0.2 0.2
    Max. 0.2 0.2 0.3 0.3 0.3 0.4
    Directivity (dB) 55 55 55 55 55 55
    Fiber Length (m) 1.0 or customized
    Fiber Type Corning SMF-28e or customized
    Wavelength Dependent Loss (dB) Typ. 0.2 0.2 0.2 0.3 0.3 0.3
    Max. 0.3 0.3 0.3 0.5 0.5 0.5
    Temperature Stability (-40~+85°C) (dB) Typ. 0.3 0.3 0.3 0.4 0.4 0.4
    Max. 0.5 0.5 0.5 0.5 0.5 0.5
    Operating Temperature (°C) -40~+85°C
    Storage Temperature (°C) -40~+85°C

    Table 3: Performance for 2×N PLC Splitter

    Note: All measurements are done at room temperature without connectors.

    Port Configuration 2×2 2×4 2×8 2×16 2×32 2×64
    Operating Wavelength (nm) 1260~1650
    Insertion Loss (dB) 4.0 7.6 11.0 14.5 17.5 21.0
    Loss Uniformity (dB) 0.8 1.5 1.5 2.0 2.5 2.5
    Return Loss (dB) 55 55 55 55 55 55
    PDL (dB) 0.2 0.2 0.4 0.4 0.4 0.4
    Directivity (dB) 55 55 55 55 55 55
    Fiber Length (m) 1.0 or customized
    Fiber Type Corning SMF-28e or customized
    Wavelength Dependent Loss (dB) 0.5 0.5 0.5 0.5 0.5 0.5
    Temperature Stability (-40~+85°C) (dB) 0.5 0.5 0.5 0.5 0.5 0.5
    Operating Temperature (°C) -40~+85°C
    Storage Temperature (°C) -40~+85°C

    Table 4: Performance for 2×N PLC Splitter

    Note: All measurements are done at room temperature with connectors.

    Port Configuration 2×2 2×4 2×8 2×16 2×32 2×64
    Operating Wavelength (nm) 1260~1650
    Insertion Loss (dB) 4.5 8.1 11.6 15.0 18.0 21.5
    Loss Uniformity (dB) 0.8 1.5 1.5 2.0 2.5 2.5
    Return Loss (dB) 55 55 55 55 55 55
    PDL (dB) 0.2 0.2 0.4 0.4 0.4 0.4
    Directivity (dB) 55 55 55 55 55 55
    Fiber Length (m) 1.0 or customized
    Fiber Type Corning SMF-28e or customized
    Wavelength Dependent Loss (dB) 0.5 0.5 0.5 0.5 0.5 0.5
    Temperature Stability (-40~+85°C) (dB) 0.5 0.5 0.5 0.5 0.5 0.5
    Operating Temperature (°C) -40~+85°C
    Storage Temperature (°C) -40~+85°C

    Ordering Information:

    Name 1U Rack Fiber PLC Splitter
    Port 12=1×2; 14=1×4; 18=1×8; 116=1×16; 132=1×32; 164=1×64; 1128=1×128;

    22=2×2; 24=2×4; 28=2×8; 216=2×16;

    232=2×32; 264=2×64; 2128=2×128

    Number of PLC Splitter None=1pc; 2=2pcs; 3=3pcs; 4=4pcs; etc
    Package R=Rack Mount
    Dimension 1=1U; 2=2U; 3=3U; 4=4U; 5=5U
    Access F=Front Access; B=Back Access
    Fiber Mode 2A=SM G.652.A; 2B=SM G.652.B;

    2C=SM G.652.C; 2D=SM G.652.D;

    5A=SM G.655.A; 5B=SM G.655.B;

    5C=SM G.655.C; 7A1=SM G.657.A1;

    7A2=SM G.657.A2; 7B2=SM G.657.B2;

    7B3=SM G.657.B3

    Connector & Adaptor SU=SC/UPC; SA=SC/APC;

    FU=FC/UPC; FA=FC/APC;

    TU=ST/UPC; TA=ST/APC;

    LU=LC/UPC; LA=LC/APC; etc

    None=without connectors

    Order information
    Q&A
    Product Tags
    Reviews

    1 reviews

    4

    5 start 5 0
    4 start 4 1
    3 start 3 0
    2 start 2 0
    1 start 1 0

    Captcha

    The maximum file allowed is 20 MB MB. You can upload images and videos. Drop files here

    1 条回复

    1. Joneru*** Pakistan

      An excellent experience. When I received it and successfully coordinated it with my device, I thought it was fantastic.

    Related Products

    Planar Lightwave Circuit Splitter – FTT...

    Planar Lightwave Circuit Splitter - FTTH Fiber Opt... Read More
    Leave Your Message