1×32 Fiber Splitter Box PLC Rack Mount 1U 19 inch
Short Description:
Designed for high-density FTTH and passive optical network deployments, this 1×32 fiber splitter Box delivers stable optical signal distribution with low insertion loss and excellent uniformity. Built with advanced PLC splitter technology, this Fiber splitter box provides reliable optical performance, wide wavelength operation, and long-term stability …Description
Order information
Q&A
Product Tags
Reviews
Description
Designed for high-density FTTH and passive optical network deployments, this 1×32 fiber splitter Box delivers stable optical signal distribution with low insertion loss and excellent uniformity. Built with advanced PLC splitter technology, this Fiber splitter box provides reliable optical performance, wide wavelength operation, and long-term stability for GPON, EPON, CATV, and FTTx applications. The 1×32 splitting configuration enables one optical input to be evenly distributed to 32 output fibers, making it ideal for large-scale subscriber access networks. Its compact rack mount structure ensures easier installation, cable organization, maintenance, and network expansion.
Additionally, its flexible compatibility means you can replace connectors or even install FBT splitters as your network scales, protecting your infrastructure investment for long-haul transmission, cable TV, or data communications.
1×32 fiber splitter Features:

rack mount plc splitter
◆ Uniform power splitting
◆ Compact package dimension
◆ Low polarization dependent loss
◆ Good channel-to-channel uniformity
◆ Environmentally and mechanically stable
◆ Low Insertion Loss and high Return Loss
◆ Wide operating wavelength range from1260nm to 1650nm
Standard:
◆ Telcordia GR-1209 and GR-1221
1x32 Fiber Splitter Application:
◆ Telecommunication networks
◆ FTTX, FTTH (Fiber to the Home)
◆ PON (Passive Optical Network)
◆ LAN & WAN
◆ CATV
Fiber splitter box Specifications:
Table 1: Performance for 1×N PLC Splitter
Note: All measurements are done at room temperature without connectors.
| Port Configuration | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
| Operating Wavelength (nm) | 1260~1650 | ||||||
| Insertion Loss (dB) | Typ. | 3.6 | 6.8 | 10.0 | 13.0 | 16.0 | 19.5 |
| Max. | 4.0 | 7.3 | 10.5 | 13.7 | 16.9 | 21.0 | |
| Loss Uniformity (dB) | Typ. | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 |
| Max. | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | |
| Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
| PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
| Max. | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 | |
| Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
| Fiber Length (m) | 1.0 or customized | ||||||
| Fiber Type | Corning SMF-28e or customized | ||||||
| Wavelength Dependent Loss (dB) | Typ. | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 |
| Max. | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
| Temperature Stability (-40~+85°C) (dB) | Typ. | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 |
| Max. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
| Operating Temperature (°C) | -40~+85°C | ||||||
| Storage Temperature (°C) | -40~+85°C | ||||||
Table 2: Performance for 1×N 1U Rack mount Fiber PLC Splitter
Note: All measurements are done at room temperature with connectors.
| Port Configuration | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
| Operating Wavelength (nm) | 1260~1650 | ||||||
| Insertion Loss (dB) | Typ. | 4.0 | 7.0 | 10.3 | 13.5 | 16.5 | 20.0 |
| Max. | 4.5 | 7.7 | 11.0 | 14.2 | 17.5 | 21.5 | |
| Loss Uniformity (dB) | Typ. | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 |
| Max. | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | |
| Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
| PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
| Max. | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 | |
| Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
| Fiber Length (m) | 1.0 or customized | ||||||
| Fiber Type | Corning SMF-28e or customized | ||||||
| Wavelength Dependent Loss (dB) | Typ. | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 |
| Max. | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
| Temperature Stability (-40~+85°C) (dB) | Typ. | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 |
| Max. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
| Operating Temperature (°C) | -40~+85°C | ||||||
| Storage Temperature (°C) | -40~+85°C | ||||||
Table 3: Performance for 2×N PLC Splitter
Note: All measurements are done at room temperature without connectors.
| Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
| Operating Wavelength (nm) | 1260~1650 | |||||
| Insertion Loss (dB) | 4.0 | 7.6 | 11.0 | 14.5 | 17.5 | 21.0 |
| Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
| Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
| PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
| Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
| Fiber Length (m) | 1.0 or customized | |||||
| Fiber Type | Corning SMF-28e or customized | |||||
| Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Operating Temperature (°C) | -40~+85°C | |||||
| Storage Temperature (°C) | -40~+85°C | |||||
Table 4: Performance for 2×N PLC Splitter
Note: All measurements are done at room temperature with connectors.
| Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
| Operating Wavelength (nm) | 1260~1650 | |||||
| Insertion Loss (dB) | 4.5 | 8.1 | 11.6 | 15.0 | 18.0 | 21.5 |
| Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
| Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
| PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
| Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
| Fiber Length (m) | 1.0 or customized | |||||
| Fiber Type | Corning SMF-28e or customized | |||||
| Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Operating Temperature (°C) | -40~+85°C | |||||
| Storage Temperature (°C) | -40~+85°C | |||||
1×32 fiber splitter Ordering Information:
| Name | 1U Rack Fiber PLC Splitter |
| Port | 12=1×2; 14=1×4; 18=1×8; 116=1×16; 132=1×32; 164=1×64; 1128=1×128;
22=2×2; 24=2×4; 28=2×8; 216=2×16; 232=2×32; 264=2×64; 2128=2×128 |
| Number of PLC Splitter | None=1pc; 2=2pcs; 3=3pcs; 4=4pcs; etc |
| Package | R=Rack Mount |
| Dimension | 1=1U; 2=2U; 3=3U; 4=4U; 5=5U |
| Access | F=Front Access; B=Back Access |
| Fiber Mode | 2A=SM G.652.A; 2B=SM G.652.B;
2C=SM G.652.C; 2D=SM G.652.D; 5A=SM G.655.A; 5B=SM G.655.B; 5C=SM G.655.C; 7A1=SM G.657.A1; 7A2=SM G.657.A2; 7B2=SM G.657.B2; 7B3=SM G.657.B3 |
| Connector & Adaptor | SU=SC/UPC; SA=SC/APC;
FU=FC/UPC; FA=FC/APC; TU=ST/UPC; TA=ST/APC; LU=LC/UPC; LA=LC/APC; etc None=without connectors |
Order information
Q&A
Download Offline Documentation – Rack Mount PLC Splitter datasheet
Related Article: How to Choose Fiber Optical Splitter
Product Tags
Reviews
1 条回复
An excellent experience. When I received it and successfully coordinated it with my device, I thought it was fantastic.