5port FE VDSL2 Router with wifi
Short Description:
1 Product Descriptions The BD-VDSL-V75 5-port FE ( 2*2 )11n USB2.0 Ethernet Router is a versatil…Description
Specification
Application
Order information
Q&A
Product Tags
Reviews
Description
1 Product Descriptions
The BD-VDSL-V75 5-port FE ( 2*2 )11n USB2.0 Ethernet Router is a versatile, high-speed remote router for home and the small office.
2 Product Specifications and Features
2.1 H/W Features
2.1.1 Specification
Key Components / Connectors / Performance | |
VDSL2 Chipset | MT7510 |
VDSL2 LineDriver | MT7555 |
WIFI Chipset | internal |
Flash Memory | 128Mbytes |
SDRAM for CPU | 512Mbit DDR2 |
Console | Internal console port (4 pin) |
ITU-T K.21 | Complied |
Interfaces (TR-068 compliant) | |
5 | 4x 10/100Base-TX MDI/MDIX RJ-45 port 1x 10/100/1000MBase-TX MDI/MDIX RJ-45 port Compliant with following standards: 1. IEEE 802.3/802.3u 2. Hardware based 10/100/1000M, full/half, flow control autonegotiation 3. Non-blocking wire speed reception andtransmission 4. Full duplex IEEE 802.3x flow control and halfduplex back-pressure flow control 5. Broadcast storm protection 6. Automatic address learning, address aging andaddress migration 7. Integrated address Look-Up Engine, 1 K absoluteMAC addresses supported |
WAN | 1x inner pair RJ-11 VDSL2 port
Data Rate: Downstream: Max up to100Mbps Upstream: Max up to 50Mbps Rate Adaptation: Data rate auto-negotiate in 32 kbps increments Performance: |
2.1.2 LED indicators
Location | LED Indicative | Color | Status | Description |
Power | Green/Red | Solid Light | Power on | |
Light off | Power off | |||
LAN1~4 | Green | Solid Light | Device connected to LAN port | |
Blinking | LAN Activity present | |||
Light off | No Activity | |||
WIFI | Green | Solid Light | Wireless enable | |
Blinking | Date transmission | |||
Light off | Wireless disable | |||
WPS | Green | Solid Light | WPS device connected | |
Light off | No WPS device connected | |||
Blinking | Negotiating | |||
USB | Green | Solid Light | Usb connected | |
Light off | No usb connected | |||
Blinking | Date transmission | |||
DSL | Green | Solid Light | DSL good sync. | |
Blinking | DSL attempting sync. | |||
Light off | No carrier signal | |||
Internet | Green/Red | Solid Light | IP connected | |
Light off | Power off | |||
GE WAN | Green | Solid Light | Device connected to WAN port | |
Blinking | WAN Activity present | |||
Light off | No Activity |
2.2 S/W Features
Feature Item | Feature | Detailed Description |
VDSL Compliance
| G.993.2
| Vdsl profiles supported: 8a/b/c/d , 12a/b, 17a
|
US0 | ||
Diagnostics mode/DELT
| ||
Dying GASP
| ||
PhyR
| ||
Virtual Noise
| ||
Both Annex A and Annex B
| Both Annex A and Annex B band plans
| |
WIFI Compliance | IEEE 802.11b/g/n | |
Support 2×2 antennas | ||
Support 2-stream spatial multiplexing up to 270Mbps | (Can upgrade to 300Mbps) | |
Support MCS 0-15 and MCS 32 modulation and coding rates | ||
Support 20M and 40M channels | ||
Support for STBC in both TX and RX | ||
Network Protocols and Features | RFC2684 VC-MUX, LLC/SNAP encapsulations for bridged or routed packet | VC-MUX for any connection type |
RFC2364 PPP over
| RFC2364 LLC/NLPID
| |
AAL5 | encapsulation for PPPoA | |
802.1q/1p VLAN over RFC2684 Bridge encapsulation | 802.1q header insertion toward WAN and de-insertion toward LAN over RFC2684 bridge mode over AAL5. Supports multiple VLANs on multiple PVCs and mapping VLANs, PVCs and physical LAN port to multiple bridges. | |
PPPoA | Support AUTO, PAP, CHAP, MS- CHAP authentication Added static IP address assignment. | |
PPPoE | Support AUTO, PAP, CHAP, MS- CHAP authentication Added static IP address assignment. | |
Multiple PPPoE sessions on single PVC | Allows multiple PPPoE sessions on one PVC. | |
PPPoE pass-through | Supports concurrent PPPoE clients inside the modem and PPPoE clients on the LAN devices | |
PPPoE – filtering of non-PPPoE packets between WAN and LAN | Previously only filtered non- PPPoE packet from LAN to WAN, now works in both directions. | |
Auto-clean-up remote staled PPP sessions at BRAS | Clean up staled PPP sessions (PPPoE and PPPoA) at ISP BRAS after ADSL link goes down then up or after modem reboots, if scratch pad is enabled on top boot flash. | |
IPoA | ||
MER (a.k.a IP over Ethernet over AAL5) | ||
WAN to WAN traffic blocking in bridge mode | ||
Second IP address on LAN interface | Only public IP address and no DHCP on second IP address. | |
ARP | ||
DNS relay | ||
DNS server fallback in DNS Relay | Launch dnsprobe process when both primary and secondary DNS’s are assigned. Probe primary DNS status and fallback to secondary DNS. When primary DNS is up again, switch back to primary DNS. | |
DHCP server | ||
DHCP client | ||
DHCP Relay | DHCP relay agent for IPoA and MER type of WAN connections. | |
NAPT | ||
IGMP Proxy | IGMP v1/v2 | |
IGMP Snooping | IGMPv1/v2 snooping in bridge mode. Added blocking mode. | |
RIP v1/v2 | Enable RIP over multiple WAN interfaces | |
Dynamic DNS | Automatic update WAN IP address when it is changed to dyndns.org and/or TZO DDNS operator. | |
LAN port to VC mapping | Supports traffic mapping between a group of LAN port to a PVC. | |
Ethernet as WAN interface. | Added Ethernet as WAN interface to support PPPoE or IP over Ethernet. | |
Multiple Protocol VLAN Mux | Support multiple protocols on single PVC using VLAN ID | |
Multiple Service PVC | Support PPPoE, Bridge, and MER services over a single PVC | |
Firewall | Stateful Inspection | SPI Fire Wal |
Denial of Service attack | Passed DOS attacks: ARP Attack, Ping Attack, Ping of Death, Land, SYNC, Smurf, Unreachable,Tear Drop | |
TCP/IP/Port/interface filtering rules | Support both incoming and outgoing filtering. | |
MAC Layer Filtering | Added IGMP in protocol menu. Filter MAC frames based on protocol type, source/destination MAC address, direction | |
Day-time Parental Control | ||
VPN | IPsec VPN(optional) | Support VPN connection to remote VPN gateway. |
QoS | IP/Bridge/802.1p QoS | Supported both routed and bridged mode PVCs for packet level QoS: classification rules, priority queuing using ATM TX queues, IP TOS/Precedence, 802.1p marking. Added DiffServ DSCP marking and src/dest MAC addresses classification. |
Configuration and Management | Web based GUI | |
Embedded web server | ||
Download image via HTTP or tftp client | ||
Download image via FTP server | ||
Download image via TFTP server | ||
Command Line Interface via serial port, telnet, or ssh | added dumpcfg, sntp commands. Added option to tftp, adsl, wan, ppp commands. Upgrade sshd to version 0.46. | |
Menu-driven CLI via serial port or telnet | Added dump configuration. | |
Universal Plug and Play (UPnP) Internet Gateway Device (IGDv1.0) | V2.14L.02: Upgraded UPnP with latest version. Added support for ADSL IGD. Enable/disable UPnP without reboot. | |
SNMP v1/v2c agent(optional) | ||
SNMP MIBs: rfc2662 ADSL line MIB, rfc2515 ATM MIB, MIB-II | Support GET only except GET/SET for system MIB and ifAdminStatus in ifTable. | |
Date/time update from SNTP Internet Time Server | Automatic synchronize date and time with Internet Time Servers and local time zone setup. Display Date/time in device info and syslog. Added SNTP command. | |
Daylight saving zone | ||
TR-69(optional) | Support 273 parameters,digest/certificate/SSL security. Support proprietary parameters implementation without tr69c framework sources | |
Code support | G.711( A law & u Law), G.723.1, G.726, G.729,etc
| |
Silence suppression | Support Silence suppression |
3 Mechanic & ID Design
3.1 Outlook
(TBD)
3.2 Case
(TBD)
3.3 Physical & Environment
3.3.1 Power
– Input: 100-240VAC, 50/60Hz (Region dependent)
– Output: 12V DC,1.5A (Switch)
– Dying Gasp: Supported
– Power Switch: Push button supported
– Reset Button: Reset to factory default by pushing button
– Wifi Buttom: Push button supported
– WPS Button: Push button supporter
3.3.2 Operation Temperature
– 0℃ to 45℃
3.3.3 Storage Temperature
– -4℉ to 149℉ (-20℃ to 70℃)
3.3.4 Humidity
– 5% ~ 95% non-condensing
4 Certification Requirements
4.1 EMC/RF Certificates and Test Reports
Request | EMI/EMC Test Report | Class A | Class B | Region & Country requirements |
CE Report (89/336/EEC(EN55022/24), 2004/108/EC) | EU | |||
FCC report(FCC CFR 47 Part 15 B) | US | |||
IC report(ICES-003) | Canada | |||
IC report(ICES-006) | Canada | |||
C-Tick Report(AS/NZS CISPR 22) | New Zealand & Australia | |||
VCCI Report(CISPR 22) | JAPAN | |||
MIC report | KOREA | |||
Anatel | Brazil | |||
BSMI | Taiwan | |||
CCC | China | |||
Other’s |
4.2 Telecom Certificates and Test Reports
Request | Telecom. Test Report | Telecom (RJ-11 Port link to PSTN) | Region requirements |
CE Report (R&TTE:1999/5/EC) TBR-21 | European union(EU) | ||
FCC Report (FCC CFR 47, Part 68)
| US /FCC ID(3P7XXXXXX..) | ||
IC Report (CS-03) | Canada /IC ID (4216AXXXX…) | ||
A-Tick Report | New Zealand & Australia | ||
NCC(PSTN01) | Taiwan | ||
Anatel | Brazil | ||
BSMI | Taiwan | ||
CCC | China | ||
Other’s |
4.3 Safety Certificates and Test Reports
Request | Certifications | Standards | Region requirements |
CE LVD report (LVD:73/23/EEC) | EN60950-1: 2001 | European Union | |
UL/cUL Listed Mark | UL/CSA 60950-1 | US / Canada | |
CSA International Mark | IEC60950-1 UL60950-1 CSA60950-1 EN 60950-1 | World US Canada European Union | |
CB Report | IEC60950-1: 2001 EN60950-1 :2001 | World European Union | |
Other’s requirements |
4.4 Reliability Test Reports
No. | Requ ired | Test Items | Refer to Standards |
1. | MTBF of Prediction Report | Bell-core TR-332, Issue 6 or Telcordia SR-332, Issue 1 | |
2. | MTBF of Endurance test Report | SPEC | |
3. | MTBF of Demonstration test Report | SPEC | |
4. | Free Fall(Drop)Test Report | IEC 60068-2-32 | |
5. | Random Vibration Test Report | IEC 60068-2-34: 1973 | |
6. | Storage Test Report | IEC 60068-2-48 | |
7. | Operation Cold(low temperature) Test | IEC 60068-2-1 | |
8. | Operation Dry Heat(High temperature) Test | IEC 60068-2-2 | |
9. | Operation Temperature Cycles Test | IEC 60068-2-14 | |
10. | Thermal Shock Test | IEC 60068-2-14 | |
11. | Damp Heat Steady State test | IEC 60068-2-78 | |
12. | Thermal Profile Test | D-Link SPEC | |
13. | ESD Simulation Test report | IEC 61000-4-2 Air Discharge: ±8KV Discharge: ±4KV | |
14. | High / Low Temperature Start Test | SPEC | |
15. | Parts on/off & Insert/pulling Test | SPEC | |
16. | Acoustic Noise test | EN 27779 & ISO 7779 |
4.5 RoHS Requirement
4.5.1 Level A of Substance limitation requirements table (for appliances & accessories)
Level | No. | Description | Limitation/ ppm |
A | A1 | Cadmium/ Cadmium Compounds | 80 |
A2 | Hexavalent Chromium/ Hexavalent Chromium Compounds | 800 | |
A3 | Lead/ Lead Compounds | 800 | |
A4 | Mercury/ Mercury Compounds | 800 | |
A5 | Polybrominated Biphenyls (PBBs) | 800 | |
A6 | Polybrominated Diphenylethers (PBDEs) | 800 |
4.5.2 Level A of Substance limitation requirements table (for Packing)
Level | No. | Description | Limitation/ ppm |
A | A1 ~ A4 | Cadmium Chromium VI, Lead and Mercury compounds | 100 |