fiber optic IPSCAPC Cable Assemblies Specification - Baudcom ...

fiber optic IPSCAPC Cable Assemblies Specification

fiber optic IPSCAPC Cable Assemblies Specification

Short Description:

Application ●    Fiber optic communications in harsh outdoor environments Outdoor communication equi…
  • Payment Terms: Paypal,western union,L/C,D/A,D/P,T/T

  • Description

    Specification

    Application

    Order information

    Q&A

    Product Tags

    Reviews

    Description

    Application

    ●    Fiber optic communications in harsh outdoor environments Outdoor communication equipment connection

    ●    waterproof fiber equipment SC port Remote wireless base station

    ●    FTTx wiring project

    ●    Fiber optic communications in harsh outdoor environments Outdoor communication equipment connection

    ●    waterproof fiber equipment SC port Remote wireless base station

    ●    FTTx wiring project

    Features

    •   Cost effective solution for in house termination.
    •   Low insertion loss and added loss.
    •  Height ofattenuation.
    •   IP67 water, dust proof and corrosionresistant
    •  The material in the jumpel cable are all-weather and UV-resistant. 6.Mechanical performance: IEC 61754-4 standard.
    •   RoHS and REACH materials compliant. 8.Cable diameter Range: 5.0mm to 4.0* 7.0mm.

    Cable Structure

    End-Face Geometry

     

    Item UPC (Ref: IEC 61755-3-1) APC (Ref: IEC 61755-3-2)
    Radius of curvature (mm) 10 to 25 5 to 12
    Fiber height (nm) -100 to 100 -100 to 100
    Apex offset (μm) 0 to 50 0 to 50
    APC angle (°) / 8° ±0.2°
    Key error (°) / 0.2° max

    End-Face Qualty (SM)

    Zone Range (μm) Scratches Defects Reference
    A: Core 0 to 25 None None  

     

     

     

    IEC 61300-3-35:2015

    B: Cladding 25 to 115 None None
    C: Adhesive 115 to 135 None None
    D: 135 to 250 None None
    E: Rest of ferrule None None

    End-Face Qualty (MM)

    Zone Range (μm) Scratches Defects Reference
    A: Core 0 to 65 None None  

     

     

     

     

    IEC 61300-3-35:2015

    B: Cladding 65 to 115 None None
    C: Adhesive 115 to 135 None None
    D: 135 to 250 None None
    E: Rest of ferrule None None

     

    Mechanical Characteristics

    est Conditions Reference
    Endurance 500 matings IEC 61300-2-2
    Vibration Frequency: 10 to 55Hz, Amplitude: 0.75mm IEC 61300-2-1
    Cable retention 100N (main cable); 50N (connector part) IEC 61300-2-4
    Strength of coupling mechanism 80N for 2 to 3mm cable IEC 61300-2-6
    Cable torsion 15N for 2 to 3mm cable IEC 61300-2-5
    Fall 10 drops, 1m drop height IEC 61300-2-12
    Static lateral load 1N for 1h (main cable); 0.2N for 5min (ranch part) IEC 61300-2-42
    Cold -25°C, 96h duration IEC 61300-2-17
    Dry heat +70°C, 96h duration IEC 61300-2-18
    Change of temperature -25°C to +70°C, 12 cycles IEC 61300-2-22
    Humidity +40°C at 93%, 96h duration IEC 61300-2-19

    Specification
    Application
    Order information
    Q&A
    Product Tags
    Reviews

    0 reviews

    5

    5 start 5 0
    4 start 4 0
    3 start 3 0
    2 start 2 0
    1 start 1 0

    Captcha

    The maximum file allowed is 20 MB MB. You can upload images and videos. Drop files here

    Leave Your Message