fiber optic IPSCAPC Cable Assemblies Specification
Short Description:
Application ● Fiber optic communications in harsh outdoor environments Outdoor communication equi…Description
Specification
Application
Order information
Q&A
Product Tags
Reviews
Description
Application
● Fiber optic communications in harsh outdoor environments Outdoor communication equipment connection
● waterproof fiber equipment SC port Remote wireless base station
● FTTx wiring project
● Fiber optic communications in harsh outdoor environments Outdoor communication equipment connection
● waterproof fiber equipment SC port Remote wireless base station
● FTTx wiring project
Features
- Cost effective solution for in house termination.
- Low insertion loss and added loss.
- Height ofattenuation.
- IP67 water, dust proof and corrosionresistant
- The material in the jumpel cable are all-weather and UV-resistant. 6.Mechanical performance: IEC 61754-4 standard.
- RoHS and REACH materials compliant. 8.Cable diameter Range: 5.0mm to 4.0* 7.0mm.
Cable Structure
End-Face Geometry
Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) |
Radius of curvature (mm) | 10 to 25 | 5 to 12 |
Fiber height (nm) | -100 to 100 | -100 to 100 |
Apex offset (μm) | 0 to 50 | 0 to 50 |
APC angle (°) | / | 8° ±0.2° |
Key error (°) | / | 0.2° max |
End-Face Qualty (SM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 25 | None | None |
IEC 61300-3-35:2015 |
B: Cladding | 25 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
End-Face Qualty (MM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 65 | None | None |
IEC 61300-3-35:2015 |
B: Cladding | 65 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
Mechanical Characteristics
est | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable retention | 100N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |