high-performance PON OTDR 1310 1550 1625nm Online Optical Detection
Short Description:
PON OTDR tester is easy to carry, high testing accuracy, simple to use, integrates 9 testing modules, OTDR/VFL/LS/OPM/Event Map/End Detection/Optical Loss Test/Ethernet test. support online FTTx/PON testing.Description
Specification
Application
Order
Downloads/FAQ
Product Tags
Reviews
Description
BD4000 series PON OTDR tester adopt 7 inch capacitance touch screen, which integrates 9 testing modules. With excellent intelligent hardware and software design, the accuracy of short fiber test and automatic test is higher. It is equipped with rich Ethernet test (Ping/PPOE, etc), support APP control.
BD4000 series is used to test the optical fiber length, loss and connection quality, and used in the engineering construction, link maintenance test. They are mainly used in urban trunk, bone trunk network and metropolitan area network. The PON OTDR tester also can be used for GPON/EPON FTTH network installation and maintenance for 1:64 split ratio.
Functions
OTDR/VFL/LS/OPM/Event Map/End Detection/Optical Loss Test/Ethernet test/Remote test/File management.
The machine also supports IOLM function.
learn more:How to Test Fiber Cable by OTDR
How does an OTDR testing fiber measure loss?
OTDR vs Optic Power Meter, Which One Should You Choose?
What is your OTDR system? Can it be compatible with Microsoft?


Specification
PON OTDR Tester Technical specifications
| Stability | CW,±0.5dB/15min(Test after 15 minutes of boot-up preheating) |
| Mode | CW/270/330/1kHz/2kHz |
| Connector | FC/UPC(Interchangeable SC、ST) |
| VFL | |
| Wavelength | 650nm±20nm |
| Output power | ≥10mW |
| Mode | CW/1Hz/2Hz |
| Connector | FC/UPC(Interchangeable SC、ST) |
| The Optical Loss Test index refers to the above light source and optical power meter index. | |
| Others | |
| Display | 7 inch color LCD + touch screen, resolution 800×480 |
| Power supply | AC/DC adapter:Input:100V~240V,50/60Hz;Output:5V/3A, 9V/2A, 12V/1.5A;Lithium battery:3.7V,10400mAh |
| Work temperature | -10℃~+50℃ |
| Storage temperature | -40℃~+70℃ |
| Relative humidity | 0~95%,Non Condensing |
| Weight | ≤1.2kg |
| Size | 215mm×160mm×50mm |
| Model | BD4000 PON OTDR testing models | ||||||||||||||||
| D32 | D35 | D38 | D42 | D45 | T0 | T1 | T2 | T3 | T4 | T5 | T6 | F1 | M1 | MD1 | MD2 | ||
| Type | SM | MM | SM/MM | ||||||||||||||
| Wavelength | 1310nm
/1550nm |
1310nm
/1490nm /1550nm |
1310nm
/1550nm /1625nm |
1310nm
/1550nm /1650nm |
1310nm
/1490nm /1550nm /1625nm |
850nm/
1300nm |
850nm
/1300nm /1310nm /1550nm |
||||||||||
| Max Dynamic
Range(dB) |
32/30 | 35/33 | 38/36 | 42/40 | 45/43 | 32
/30 /30 |
37
/35 /35 |
32
/30 /30 |
37
/35 /35 |
42
/40 /40 |
32
/30 /30 |
37
/35 /35 |
37
/35 /35 /35 |
26/28 | 26
/28 /35 /33 |
26
/28 /37 /35 |
|
| Event Blind Zone | 0.8m | 0.5m | 0.8m | 0.5m | 0.8m | 0.5m | 0.8m | 0.5m | 0.5m | 1m | |||||||
| ATT Blind zone | 4m | 3.5m | 4m | 3.5m | 4m | 3.5m | 4m | 3.5m | 3.5m | 6m | |||||||
| Test Range | 100m/500m/1.25km/2.5km/5km/10km/20km/40km/80km/125km/260km/420km | ||||||||||||||||
| Pulse Width | 3ns/5ns/10ns/30ns/50ns/80ns/100ns/200ns/300ns/500ns/800ns/1us/2us/3us/5us/8us/10us/20us | ||||||||||||||||
| Range Accuracy | ±(0.75m+ Sample interval +0.0025%×Test distance) | ||||||||||||||||
| Loss Accuracy | ±0.03dB/dB | ||||||||||||||||
| Sample Points | ≥256k | ||||||||||||||||
| Sample Resolution | 0.015m~16m | ||||||||||||||||
| Reflection Accuracy | ±2dB | ||||||||||||||||
| Loss Resolution | 0.001dB | ||||||||||||||||
| Loss Threshold | 0.01dB | ||||||||||||||||
| File Format | SOR Standard File Format | ||||||||||||||||
| Loss Analysis Mode | 4-point method /5-point method | ||||||||||||||||
| Laser Safety Level | Class Ⅱ | ||||||||||||||||
| Refresh Rate | 4Hz (Typ.) | ||||||||||||||||
| Data Storage | Internal storage:2GB(20,000 curves);External storage:64GB | ||||||||||||||||
| Connector | FC/UPC(Interchangeable SC、ST) | ||||||||||||||||
| Data Interface | USB-A、Type-C port、RJ45 LAN 10M/100M bit/s | ||||||||||||||||
| OPM | |||||||||||||||||
| Wavelength range | 800nm~1700nm | ||||||||||||||||
| Connector | Universal FC/SC/ST | ||||||||||||||||
| Test scope | -50dBm~+26dBm/-70dBm~+6dBm | ||||||||||||||||
| Uncertainty | ±5% | ||||||||||||||||
| Calibration wave | 850nm/980nm/1300nm/1310nm/1490nm/1550nm/1625nm/1650nm | ||||||||||||||||
| LS | |||||||||||||||||
| Wavelength | Consistent with OTDR output wavelength | ||||||||||||||||
| Laser Type | FP-LD | ||||||||||||||||
| Output power | ≥-5dBm | ||||||||||||||||
| Stability | CW,±0.5dB/15min(Test after 15 minutes of boot-up preheating) |
| Mode | CW/270/330/1kHz/2kHz |
| Connector | FC/UPC(Interchangeable SC、ST) |
| VFL | |
| Wavelength | 650nm±20nm |
| Output power | ≥10mW |
| Mode | CW/1Hz/2Hz |
| Connector | FC/UPC(Interchangeable SC、ST) |
| The Optical Loss Test index refers to the above light source and optical power meter index. | |
| Others | |
| Display | 7 inch color LCD + touch screen, resolution 800×480 |
| Power supply | AC/DC adapter:Input:100V~240V,50/60Hz;Output:5V/3A, 9V/2A, 12V/1.5A;Lithium battery:3.7V,10400mAh |
| Work temperature | -10℃~+50℃ |
| Storage temperature | -40℃~+70℃ |
| Relative humidity | 0~95%,Non Condensing |
| Weight | ≤1.2kg |
| Size | 215mm×160mm×50mm |
NOTE:① PON ODTR Testing ambient temperature is 25℃±2℃, the maximum pulse width, the average time is more than 180s.
②Test conditions of event blind zone are min range, min pulse, reflection loss of optical fiber end surface (> 45dB), typical value.
Configuration List
| NO. | Name | Quantity | Remarks |
| 1 | Host | 1 | Including battery |
| 2 | AC/DC adapter | 1 | |
| 3 | U-disk (including analysis software, instructions) | 1 | |
| 4 | Data line | 1 | |
| 5 | OTDR SC adapter | 1 | |
| 6 | OPM SC adapter | 1 | |
| 7 | User’s Manual | 1 | |
| 8 | Calibration Certificate | 1 | |
| 9 | Qualification Certificate/After-sales Service Guarantee Card | 1 | |
| 10 | Clean cotton slices | 10 | |
| 11 | Leather knob | 1 | |
| 12 | Instrument backpack (with straps) | 1 |
Application
PON testing video
Order
Downloads/FAQ
Qustion: Please I need you to confirm that the OTDR can be used to measure active links, the OTDR I need now is for carrier-rated point-to-point links.
Answer: Our Optical Time Domain Reflectometer can be used in active links. The OTDR’s 1625nm or 1650nm will work in your acitive optical system.
Qustion: What the minimum length your OTDR can measure
Answer: 5 meter
Qustion: What is the maximum number of splitter it show?
Answer: can show 64 channel, but maybe the precision is not high. Till now, no any OTDR supplier can test 64channel with high precision.
for 32channel application, our otdr machine testing is precise.
Question: Before the splitter what’s minimum fiber we Shall put
Answer: 50 meters
Question: If the first level splitter 1×8 and second level 1×8 splitter,
My question is if the otdr can access the measurements by accessing the first and second level splitters or (Nap box)
Answer: yes.
Question: In gpon and xgpon system, the OTDR also can measures, right? Can this OTDR test MA5800 XG-PON?
Answer: yes, the PON OTDR can support GPON and XGPON system, can test online or offline.
Qustion: Is it activated? If the iolm comes ready to use.
Answer: Yes, it has been activated. You can use the function directly.
Can Baudcom OTDR support Spanish?
BD4000 OTDR can support Spanish language. When you place order, please let us know the language the you need.
What is your OTDR system? Can it be compatible with Microsoft?
Product Tags
Reviews
3 responses
El respaldo tecnico de baudcom con sus productos es excelente. Tuve un problema con un Otdr y solicite el servicio de respaldo con las personas del laboratorio se conectaron con el Otdr a travez de mi PC y solucionaron el problema.
Es un buen Otdr, tiene buen desempeño y cuando se miden Splitters se puede apreciar su medicion con sus respectivas atenuaciones. Tiene buen Software de manejo del Otdr es amigable y muy facil de manejar.
Je*** Alb**** Ram****
Fit**** R** SAS
Bogotá, Colombia
We have cooperated with Baudcom years. Baudcom OTDR quatity is very high, BD4000 and BD6000 all worked stable. Baudcom engineers can response soon for any technical support.